Two cavities are where the U-value comes from
A sealed cavity resists heat flow because the gas inside it is still. Argon is a real but modest gain over air in the same 9 mm gap, and it only holds if the unit stays sealed at the edge, which is why it is offered as an option rather than treated as the deciding factor. The larger lever is a low-emissivity coating, which suppresses radiant transfer across the cavity and is also an option rather than a standard. Beyond that, one cavity roughly halves the conductance of a single pane and a second halves it again with diminishing returns, because the panes and the frame still conduct. The number on a datasheet is centre-of-glass, and no whole entrance reaches it.